<!DOCTYPE html>
<html>
	<head>
    	<meta http-equiv="Content-Type" content="text/html; charset=UTF-8" />
    	<meta http-equiv="Content-Language" content="en" />
		<meta name="viewport" content="width=device-width, initial-scale=1.0" />
    	<title>system-shutdown</title>
    	<meta name="Description" content="Client side shutdown command responsible for starting the service responsible for actual shutdown." />
    	<meta name="Keywords" content="goetia s6 s6-rc FreeBSD shutdown" />
	</head>
	<header>
		<p>
			<a href="//0x53.net/software/goetia/goetia-freebsd-init">goetia-freebsd-init</a>
			<br />
			<a href="//0x53.net/software/goetia">goetia</a>
			<br />
			<a href="//0x53.net/software">Software</a>
			<br />
			<a href="//0x53.net">0x53.net</a>
		</p>
	</header>
	<body>
		<h1>The system-shutdown program</h1>
		<p>
			system-shutdown is the interface to the
			<a href="//0x53.net/software/goetia/goetia-base/bin/system-shutdown-daemon.html">system-shutdown-daemon</a>.
		</p>
		<h2>Interface</h2>
		<pre>     system-shutdown -h | -p | -r</pre>
		<ul>
			<li>
    			system-shutdown writes its argument to the file <code>DIRECTIVE</code> in the envdir at the
    			<code>shutdown-directive</code> subdirectory of the
    			<a href="//0x53.net/software/goetia/rundir.html#system">system runtime directory</a>.
			</li>
			<li>
    			It continues to initiate the shutdown sequence by starting the service
    			<a href="//0x53.net/software/goetia/goetia-freebsd-init/service/system/goetia-shutdown.html">goetia-shutdown</a>.
			</li>
		</ul>
		<h2>Options</h2>
		<ul>
			<li>
    			<code>-h</code>: at the end of the shutdown sequence, halt the system.
			</li>
			<li>
    			<code>-p</code>: at the end of the shutdown sequence, poweroff the system.
			</li>
			<li>
    			<code>-r</code>: at the end of the shutdown sequence, reboot the system.
			</li>
		</ul>
		<h2>Exit codes</h2>
		<ul>
			<li>
    			system-shutdown exits 100 if wrong options were used.
			</li>
			<li>
    			Since system-shutdown is an
				<a href="https://skarnet.org/software/execline/">execline</a>
				script, it exits with an approximation
				of employed program that failed.
			</li>
			<li>
    			system-shutdown mostly uses
				<a href="https://skarnet.org/software/execline/">execline</a>
				and
				<a href="https://skarnet.org/software/s6/">s6</a>
				software, the exit behaviour of which can be looked up on
				their respective pages.
			</li>
			<li>
    			See also:
				<a href="https://skarnet.org/software/execline/exitcodes.html">execline exit code handling</a>.
			</li>
		</ul>
		<h2>Notes</h2>
		<p>
			There is a reason this program exists as part of (multiple)
			goetia-init packages and not as part of
			<a href="//0x53.net/software/goetia/goetia-base">goetia-base</a>.
			It is that some supported init systems, like
			<a href="https://skarnet.org/software/s6-linux-init/">s6-linux-init</a>
			(through <a href="//0x53.net/software/goetia/goetia-s6-linux-init">goetia-s6-linux-init</a>)
			provide their own shutdown procedure and interface.
		</p>
	</body>
</html>